HDMI Test Report

Overall Results:2 of 4 Tests Failed

Test Configuration Details
Device Description
HDMI Specification2.0
HDMI Test TypeTMDS Physical Layer Tests
Test ModeCompliance Mode
Test Session Details
Infiniium SW Version04.50.0008
Infiniium Model NumberDSOX93204A
Infiniium Serial NumberMY53180105
Application SW Version1.99.9027
Debug Mode UsedNo
Probe (Channel 1)Model: 1169A Serial: US44000259 Head: N5380A/B Atten: Not Calibrated, Using Default Atten (2.2029E+000) Skew: Not Calibrated, Using Default Skew
Probe (Channel 2)Model: 1169A Serial: US49413460 Head: N5380A/B Atten: Not Calibrated, Using Default Atten (2.0148E+000) Skew: Not Calibrated, Using Default Skew
Probe (Channel 3)Model: 1169A Serial: US49412951 Head: N5380A/B Atten: Not Calibrated, Using Default Atten (2.2029E+000) Skew: Not Calibrated, Using Default Skew
Probe (Channel 4)Model: 1169A Serial: US49412941 Head: N5380A/B Atten: Not Calibrated, Using Default Atten (2.1765E+000) Skew: Not Calibrated, Using Default Skew
Last Test Date2013-09-12 14:11:59 UTC -07:00

Summary of Results

Margin Thresholds
Warning< 2 %
Critical< 0 %

Pass# Failed# TrialsTest NameActual ValueMarginSpec Range
11HF1-2: Clock Rise Time71.096 ps-5.2 % VALUE >= 75.000 ps
11HF1-2: Clock Fall Time62.495 ps-16.7 % VALUE >= 75.000 ps
01HF1-6: Clock Duty Cycle(Minimum)49.94024.9 % >=40%
01HF1-6: Clock Duty Cycle(Maximum)50.10016.5 % <=60%


Report Detail


HF1-2: Clock Rise Time Reference: Test ID HF1-2
Test Summary: FAIL Test Description: 2 Channels Connection Model: The transition time is defined as the time interval between the normalized 20% and 80% amplitude levels. For compliance, the DUT should output the highest supported pixel clock frequency during the test.
Test Limits:>= 75.000 psRaw Clock Transition Time71.096 ps
Result Details:
Result Details
HDMIAutomationConfigTiming C 3Test Frequency(MHz)148.500Upper Threshold(%)80.000Lower Threshold(%)20.000# Edges10.999000 kTransfer Function FileC:\ProgramData\Agilent\Infiniium\Apps\HDMIHEACTest\app\config\TransferFunction\Final\Final_Wilder HDMI TPA-P_cableembed_equ_skew_n.tf4
Trial 1
Trial 1: Raw Clock Transition Time

HF1-2: Clock Fall Time Reference: Test ID HF1-2
Test Summary: FAIL Test Description: 2 Channels Connection Model: The transition time is defined as the time interval between the normalized 20% and 80% amplitude levels. For compliance, the DUT should output the highest supported pixel clock frequency during the test.
Test Limits:>= 75.000 psRaw Clock Transition Time62.495 ps
Result Details:
Result Details
HDMIAutomationConfigTiming C 3Test Frequency(MHz)148.500Upper Threshold(%)80.000Lower Threshold(%)20.000# Edges10.999000 kTransfer Function FileC:\ProgramData\Agilent\Infiniium\Apps\HDMIHEACTest\app\config\TransferFunction\Final\Final_Wilder HDMI TPA-P_cableembed_equ_skew_n.tf4
Trial 1
Trial 1: Raw Clock Transition Time

HF1-6: Clock Duty Cycle(Minimum) Reference: Test ID HF1-6
Test Summary: Pass Test Description: 2 Channels Connection Model: Confirm that the duty cycle of the differential TMDS clock does not exceed the limits allowed by the specification. For compliance, the DUT should output the highest supported pixel clock frequency during the test.
Test Limits:>=40%Clock Duty Cycle Minimum49.940
Result Details:
Result Details
HDMIAutomationConfigTiming C 3Test Frequency(MHz)148.500# Edges10.000000 kTdutyMIN(ns)3.363Transfer Function FileC:\ProgramData\Agilent\Infiniium\Apps\HDMIHEACTest\app\config\TransferFunction\Final\Final_Wilder HDMI TPA-P_cableembed_equ_skew_n.tf4
Trial 1
Trial 1: Clock Duty Cycle Minimum

HF1-6: Clock Duty Cycle(Maximum) Reference: Test ID HF1-6
Test Summary: Pass Test Description: 2 Channels Connection Model:Confirm that the duty cycle of the differential TMDS clock does not exceed the limits allowed by the specification. For compliance, the DUT should output the highest supported pixel clock frequency during the test.
Test Limits:<=60%Clock Duty Cycle Maximum50.100
Result Details:
Result Details
HDMIAutomationConfigTiming C 3Test Frequency(MHz)148.500# Edges10.000000 kTdutyMAX(ns)3.374Transfer Function FileC:\ProgramData\Agilent\Infiniium\Apps\HDMIHEACTest\app\config\TransferFunction\Final\Final_Wilder HDMI TPA-P_cableembed_equ_skew_n.tf4
Trial 1
Trial 1: Clock Duty Cycle Maximum